Aug 24, 2020 Leave a message

The Main Difference Between Air-cooled Chillers And Water-cooled Chillers

Ordinary people may think that the water chiller can be used and it does not matter what it is, but it is necessary for companies to understand the functionality of these two chillers, because large-scale applications are not only costly. Philip, there may be a big deal, and using the right one is the most important reason. So is there any difference between air-cooled chillers and water-cooled chillers? Dongyuejin chiller will give you an analysis of their differences from these three aspects today.


1. Comparison of initial investment


The necessary supporting facilities for air-cooled chillers are chilled water pumps, water separators and water collectors. But water-cooled chillers are dedicated machine rooms, cooling towers (cooling chilled water pumps), water collectors and water separators. Obviously, water-cooled chillers have a few more necessary facilities than air-cooled chillers. Because of early investment, air-cooled chillers are significantly better than water-cooled chillers.


2. Performance comparison


The heat transfer temperature difference of the water-cooled chiller condenser is generally 4. C-8. C. The heat transfer temperature difference of air-cooled chillers is generally 8°C-15°C. Under the same outdoor ambient temperature, the temperature of the cooling circulating water is lower than the outdoor air temperature, so the air-cooled chillers operate normally The condensing temperature is much higher than that of water-cooled chillers, so that air-cooled chillers consume more power than water-cooled chillers under the same cooling capacity.


3. Comparison of operating costs


The operation of the machine must use electricity, so the electricity bill is a comparable amount. That is to say, the operating benefits and power consumption of the unit should be clearly known. In addition, there must be maintenance in operation, and the cost of maintenance must also be compared. The above mentioned that the mechanical parts of air-cooled chillers are less than those of water-cooled mechanical parts. In this respect, the maintenance cost of air-cooled chillers is indeed less. For water-cooled chillers.


Industrial chillers are divided into water-cooled industrial chillers and air-cooled industrial chillers. The difference between the two is mainly in the condenser. The condenser of a water-cooled chiller mainly takes away heat by circulating cooling water, so the condenser of a water-cooled chiller is also usually called a water cannon. Unlike the water-cooled type, the air-cooled industrial chiller uses a fan for heat dissipation. Finned condensers are usually used. The fins actually refer to aluminum fins. The parts that need heat exchange are to be installed externally to achieve efficient heat dissipation, and then the hot air is extracted by a powerful fan. Therefore, when the workshop temperature is high, the air-cooled chiller will not only be affected by itself (excessive condenser temperature will directly cause the high-pressure alarm of the industrial chiller and decrease the refrigeration capacity), it will also have a direct impact on the workshop temperature. The advantages of water-cooled chillers are obvious. Water-cooled industrial chillers require cooling towers to circulate cooling water to cool down. Therefore, to use water-cooled chillers, you need to install cooling towers, cooling water circulating pumps, and pipelines, which is more complicated. Compared with air-cooled industrial chillers, the ease of movement pales in comparison. But in most cases, the factories are already equipped with cooling water circulation systems.