Fault And Treatment Of Precision Filter

1. The end cover of precision filter is not tight

Tighten the end cap

2. Pipeline filter piping valve not opened

Open the valve

3. Low intake pressure

Check the cause and increase the intake pressure

4. Air leakage of O-ring of pipeline filter

Exchange

5. Air leakage in piping


Repair piping

The pressure drop increases

1. The filter element is blocked or the adsorption capacity is too large

Replace the filter element

2. High intake impurity load

Pretreatment was carried out

3. Water accumulation in filter cartridge of pipeline filter

Find out the cause and drain the remaining water

4. Automatic drainer failure

Adjust, repair or replace the drain

5. The filter is not installed horizontally

Re install

Filtration

The effect is poor