Energy Saving Oil Temperature Control Unit
Specifications:
|
Max temperature(℃) |
300 |
Heat power (KW) |
24 |
|
Pump head(M) |
27 |
Max pump flow M³/H |
3 |
|
Pump Power: |
1.5 |
Tank (L) |
25 |
|
Transfer medium |
Oil |
Cooling way |
Indirect |
|
Control precision(℃) |
PID +/-1℃ |
Pipe |
2-1/2 |
|
Alert function: pump reversal/oil shortage/overheating/overload/oil overflow |
|||
Features:
1.Perfect safety protection, fault display, repair, maintenance without professional personnel
2.304 stainless steel integrated pipeline
3.Heater Selector Switch (Automatic)
4.Heater Selector Switch (Manual)
5.High-Temperature Stainless Steel Braided Hose
6.Leak Containment Cabinetry
7.Control Options - remote set point and re-transmission, communication ports, and much more
8.Heat Exchanger Flow Control System
9.Other Voltages, Phases, Frequencies
10.Overhead Piping Kit
11.Phase Indicator
12.Process Fluid Purge via Switch
The reasons why the oil temperature machine cannot heat up normally are as follows
1. If the heating tube is defective or damaged, the oil temperature machine cannot be heated, so the temperature cannot be reached;
2. The abnormality of the thermostat causes the abnormal display of the temperature of the heating oil temperature machine;
3. The pipeline of the machine is too long, the head and pressure of the circulating pump cannot meet the requirements, and the heat generated by the heating of the oil temperature machine cannot raise the temperature of the heated object;
What is the fault that the mold temperature machine lacks media?
The coal shortage alarm is either water shortage or oil shortage. Check to see if the system waterway or fuel tank is missing. The way to cancel the alarm is to add water or heat transfer oil to resume normal use.
Mold temperature machine media failure refers to lack of media (water or oil).
Oil temperature controller, please check whether the liquid level in the lower oil tank is normal. If it is not normal, just add heat-conducting oil to the fuel tank; if it is normal, you can first check whether the float level switch is stuck, screw it out and take a look. If the above problems are eliminated, you need to check whether there is any problem with the control panel of the mold temperature machine.
FAQ
Q1:When can I get the price?
A:We will offer you the best quotation asap on the date of your inquiry.
Q2:Where is your company?
A:Zhejiang,China.
Q3:Where is your loading port?
A:Shanghai.
Hot Tags: energy saving oil temperature control unit, China, factory, suppliers, manufacturers, customized, price, made in China, heat transfer oil system, industrial temperature controller project, mould temperature controller, Oil Temperature Control Units, Oil Temperature Heater, rolls temperature controller