According to the differences of heat dissipation method, screw chiller can be divided into water-cooled screw chiller and air-cooled screw chiller.
1. The screw chiller [1] summarizes the selection of water chiller when considering the cold load and its use. To deal with the cooling system with long time of low load operation, it is advisable to choose a multi-machine head plug compressor or screw compressor unit, which is convenient to adjust and save energy.
2. When using the screw-type cold water chiller to summarize the chiller unit, the unit with higher performance coefficient value is considered. According to the statistics, the normal water chiller is under 100% load all year and the running time is less than 1/4 of the running time. The operating time ratio of 100%, 75%, 50% and 25% load in the running time is roughly 2.3%, 41.5%, 46.1% and 10.1%. In this case, when the chiller is choosing the chiller, it is considered that the efficiency curve is relatively flat. At the same time, in the design of the selection of the water unit load adjustment category. Multi - head screw - type cold water chiller can be selected according to the fact.
3. When choosing the chiller, pay attention to the condition of the surface condition. The cooling capacity of the chiller is related to the following factors: a, cold water outlet temperature and flow rate; B. Water inlet temperature, flow rate and fouling coefficient of cooling water.
4. When using the screw-type chiller, the normal operation of the unit should be paid attention to, and the current limit of the motor is the current value of the shaft power under the surface condition.
5. In the design of an overview of the screw-type chiller, it is noted that the outlet temperature of the cold water should not exceed 15 meters under the surface condition, and the temperature of the outdoor dry bulb of the air cooling unit should not exceed 43. If the above categories must be crossed, if the use category of the compressor can be understood, whether the power of the motor is enough.
Principle of screw water chiller:
The screw type chiller is used for the key parts - the compressor adopts the screw type of the screw type water chiller, the unit is the gas refrigerant which is produced by the evaporator. After adiabatic compression of compressor, it becomes high temperature and high pressure state. The compressed gas cooler, in the condenser, iso-pressure cooling condensate, after condensing, changes into liquid refrigerant, then the throttle valve expands to the low pressure, and becomes a gas mixture. The liquid refrigerant under low temperature and low pressure can absorb the heat of the cold matter in the evaporator, and then turn it into a gas cold medium. The gaseous cold media is re-entered into the compressor through a pipeline and begins a new cycle. This is the four processes of the freezing cycle and the main working principle of the screw chiller.