In order to correctly select a small lyophilizer, we must first understand the small lyophilizer.
1、 Common name
The common names of small freeze-drying machines are: laboratory freeze-drying machine, experimental freeze-drying machine, small freeze-drying machine, small freeze-drying machine, laboratory freeze-drying machine, laboratory vacuum freeze-drying machine, small vacuum freeze-drying machine, experimental freeze-drying machine, experimental freeze-drying machine, etc.
2、 Introduction
Vacuum freeze-drying technology, also known as freeze-drying technology, rapidly freezes the articles at low temperature, and then sublimates the frozen water molecules in the articles directly into the process of water vapor escape in the vacuum and low temperature environment. The products obtained by freeze-drying are called freeze-dried products, so the freeze-dried articles will not damage the original chemical structure and morphology of the samples, The bioactive materials can still restore the conformation and biological function before freeze-drying after re dissolution.
Freeze drying technology is widely used in scientific research and production in chemical industry, food, materials, medicine, biological products and other fields, such as biological products and biochemical drugs; Microorganisms and algae; There are also drying operations of vulnerable and easily oxidized substances, such as biological specimens and biological tissues, historical archives, dehumidification and preservation of cultural relics, dehumidification of microporous parts, etc. Vacuum freeze dryer is referred to as freeze dryer for short. The basic components of Laboratory Series freeze dryer include vacuum pump, cold trap, freeze-drying chamber, vacuum and temperature control system, and other functional accessories, such as multi manifold, gland device, ordinary type, etc. Factors to be considered when selecting a small lyophilizer for laboratory use.

3、 Classification
1.)According to freeze-drying method
When the sample quantity is small, the method of directly freezing and drying the sample in the cold trap without pre freezing in the ultra-low temperature refrigerator is called process a; The method of pre freezing the sample outside the cold trap and then freeze-drying is called process B.
A lyophilizer that supports process a lyophilization. This kind of machine that does not require manual operation from pre freezing to freeze-drying of samples is called in-situ freeze-drying machine. In situ freeze-drying machine is the development direction of freeze-drying machine. It is an ideal choice for exploring the freeze-drying process. It is especially suitable for the freeze-drying of medicine, biological products and other special products.
A lyophilizer that supports process B lyophilization. The freeze-drying chamber and cold trap are independent upper and lower structures. The freeze-drying chamber has no pre freezing function and can generally be classified as process B freeze-drying mode. This type of freeze dryer needs manual operation when it is transferred to the drying process after the pre freezing of materials. Most of the experimental lyophilizers are bell jar type, and the lyophilization chamber mostly adopts transparent plexiglass cover, which is convenient to observe the lyophilization of materials.
2.)Select by function
Ordinary shelf type: freeze drying of materials in bulk in the material tray.
Type with capping device: it is applicable to the lyophilization of Xilin bottles. During the preparation of lyophilization, the materials are sub packed into Xilin bottles as required. After the floating cap is closed, the lyophilization can be completed by operating the capping device to press the cap. This operation can avoid secondary pollution and re absorb water, which is easy for long-term storage.
Multi manifold type: use multi manifold or freeze-drying chamber flask to dry the materials spun frozen on the inner wall of the flask. At this time, the flask is connected to the manifold outside the drying oven as a container. The materials in the flask are heated at room temperature. Through the multi manifold switch device, the flask can be removed or installed at any time as required without shutdown. With pre freezing function: in the process of material pre freezing, the cold trap is used as the pre freezing chamber to pre freeze the material. In the drying process, the cold trap is used as a water trap to capture the overflow water of the material. For the freeze dryer with pre freezing function, the pre freezing and drying of materials in the freeze-drying process are completed on the freeze dryer. The use efficiency of the freeze dryer is high and the cost of low-temperature refrigerator is saved.
4、 Factors to be considered when purchasing laboratory lyophilizer
1. )Manufacturer's choice
Strong freeze-drying machine manufacturers are preferred, and they have many years of professional experience and expertise in the production of freeze-drying machines, and support non-standard customization and solutions.
2. )Cold trap temperature
The cold trap is a device placed between the freeze-drying chamber and the vacuum pump to capture steam. The lower the cold trap temperature is, the stronger the capture capacity of the cold trap is. However, the lower the cold trap temperature is, the higher the refrigeration requirements are, and the machine cost and operation cost are relatively high.
3.) Ice coagulation
The amount of steam that can be captured by the cold trap is related to the total amount of water or other solvents sublimated in the laboratory every day.
4.) Limit vacuum
The extreme vacuum degree reflects the leakage of the lyophilizer and the pumping efficiency of the vacuum pump. The vacuum degree of the experimental operation should be within a reasonable range. If the vacuum degree is too high, it is not conducive to heat transfer, but the drying speed decreases.
5. )Control display system
The laboratory series of freeze-drying machines are mainly used for freeze-drying of materials, small batch production and freeze-drying process condition test.
The control system shall be able to display the freeze-drying process parameters in real time, such as cold trap temperature, vacuum degree, stage time and total process time; Set, modify and effectively implement freeze-drying process procedures; It is recommended to have a communication interface to facilitate data acquisition and storage.
6. )Freeze drying method and function
According to specific samples, there are different options for freeze-drying. The common laboratory freeze-drying experiments adopt the process B method, that is, freeze-drying in the freeze-drying chamber or hanging the bottle for freeze-drying. If it is freeze-drying in the freeze-drying chamber, it is necessary to select the freeze-drying chamber, the Xilin bottle for freeze-drying, and the capping device; In case of hanging bottle lyophilization, multi manifold shall be selected, which is suitable for round bottom flask, wide mouth filter bottle or ampoule bottle, but pay attention to whether corresponding adapter needs to be selected for combination; If the samples involved in the user's test are both freeze-dried in the cavity and freeze-dried in the external bottle, the freeze-drying cavity with external hanging port can be selected.
Different experiments and samples have different functional requirements for the lyophilizer. Generally speaking, shelf type lyophilizer is generally recommended for the lyophilization of food, Chinese herbal medicine, powder materials and other samples; For the operation of vials, the lyophilizer with capping device must be selected; It is suggested to use hanging bottle for freeze-drying preservation of microbial strains, and ampoule adapter must be selected for freeze-drying; If you want to study the freeze-drying process curve, you must select the model that the controller can support the eutectic point test device and software.
6、 Summary: select the lyophilizer according to the specific needs.